34
Increase/decrease
Select
Select
Select
Engine revolution speed selection
or
Pr
【Setting Menu】→【Ne-Point】
Air correction engine RPM setting
2
.
Select [Ne-Point] in the
setting menu
1
.
Select [Setting] in the
main menu
Main menu
Setting menu
or
Nx
■Setting range The value in parentheses is the initial value
Ne Point【Engine revolution point】800∼9800 [rpm]
(1000.1600.2200.2800.3400.4000.4600.5200.5800.6400.7000.7600)
※Settable by 200 rpm steps
3.
The air correction engine RPM setting mode is set
or
Pr
Ne : Engine RPM
Ne01<Ne02<Ne03<Ne04<Ne05<Ne06<Ne07<Ne08<Ne09<Ne10<Ne11<Ne12
For Ne02, the engine revolution speed cannot be set to a lower value than that of
Ne01. The same can be said for the other revolution points,
or
or
Enter
Enter
Go back
Go back
or
Engine revolution speed setting
Kommentare zu diesen Handbüchern